  1 description the icm5 serial converter module provides the capability of interfacing equipment with rs-485 serial communications to equipment with rs-232 communications while providing three way isolation. data format of the rs-232 and rs-485 equipment must be the same. the unit can be configured for full duplex (rs-422), or half duplex (rs-485) operation. in half duplex mode, the rs-485 driver is automatically enabled using the leading edge of the first character that is received on the rs-232 side. after the last character is received, the converter waits one character time (at the selected baud rate) to disable the rs-485 driver. an external dc power source (+9 to 26 vdc) is required to power the icm5. the external power source and rs-485 communications connections are made via a 7-position removable terminal block located on the front of the module. a modular rs-485 connector is also provided for fast and efficient connection to other red lion devices that use a modular connector. the rs-232 connection is provided via a standard d-sub 9-pin male connector. the icm5 can be configured for dte or dce operation, allowing the use of modem or null- modem cables. there are 3 leds that can be viewed from the front of the converter module. a green power led indicates power is on, a red rs-232 txd led flashes when the module is transmitting, and a green rs-232 rxd led flashes when the module is receiving. the unit is equipped with a universal mounting foot for attachment to standard din style mounting rails, including top hat profile rail according to en 50 022 - 35x7.5 and 35x15, and g profile rail according to en 50 035 - g32. safety summary all safety related regulations, local codes and instructions that appear in the manual or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. if equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. specifications 1. power : +9 to 26 vdc @ 125 ma maximum. 85 ma typical power supply must be class 2 or selv rated. 2. rs-232 voltages : receive data pin : 30 vdc max. mark condition : 0.8 vdc space condition : 2.4 vdc transmit data pin : mark condition : -8 vdc (typ.) space condition : + 8 vdc (typ.) 3. rs-485 voltages : differential output voltage : 5 vdc max. under no load differential input voltage : 5 vdc max. mark condition : -0.2 vdc space condition : + 0.2 vdc rs-485 drive capability : up to 32 rs-485 receivers connected in parallel rs-485 drive disable time : one character time (at the set baud rate) 4. maximum cable length : rs-232 : 50 feet (15.24 m) rs-485 : 4000 feet (1219.2 m) 5. baud rate : 9600 min., 115200 max. 6. isolation : 1000 vdc 7. environmental conditions : operating temperature range : 0 to 50 c. storage temperature : -40 to + 75 c operating and storage humidity : 85% max. relative humidity (non-condensing) from 0 to 50 c model icm5 C three way isolated serial converter module (rs-232c/rs-485) (85.1) 3.35 (89) 3.5 .39 (10) (25) .98 comm comm pwr txd rs485 m2869 x made in u.s.a . red lion controls 57600 bau d 115200 bau d 38400 bau d off 4 wire/ on 2 wire off 422/ on 485 120 terminatio n off 4 wire/ on 2 wire off dce/ on dt e off dte/ on dce off dte/ on dc e off dce/ on dt e off 422/ on 485 york, pa . model icm5 must be set in groups switches * * * * * @ 125ma max. 9-26vdc class 2 19200 bau d 9600 baud pull up pull down rs232 10 6 2 1 3 5 4 7 9 8 nc 1 3 4 5 2 6 7 sply pwr on + vdc 422 485/ leds on rxa rxb txb txa 2 1 4 3 5 6 7 dimensions in inches (mm) caution: read complete instructions prior to installation and operation of the unit. ? 9 pin d-sub connector for rs-232 connection ? switchable termination and biasing resistors ? modular rj jack or screw terminal for rs-485 connection ? allows communications between rs-232 control equipment and products with rs-422/rs-485 serial communications ? three way isolation protects serial equipment from ground loops (1000 vdc) ? automatic rs-485 driver control ? dip switch selectable baud rates 9600, 19200, 38400, 57600, 115200 ? wide dc input power range (+9 to 26 vdc) ? half duplex (rs-485) and full duplex (rs-422) ? led indication for rxd, txd, and power ? universal mounting foot for din rail installation ? selectable dte & dce operation works with any rs-232 cable bulletin no. icm5-e drawing no. lp0529 released 09/14 tel +1 (717) 767-6511 fax +1 (717) 764-0839 www.redlion.net ul recognized component, file # e179259
2 vibration to iec 68-2-6 : operational 5 to 150 hz, 2 g. shock to iec 68-2-27 : operational 30 g. altitude : up to 2000 meters 8. certifications and compliances : safety ul recognized component, file #e179259 recognized to u.s. and canadian requirements under the component recognition program of underwriters laboratories, inc. iec 61010-1, en 61010-1: safety requirements for electrical equipment for measurement, control, and laboratory use, part 1. electromagnetic compatibility immunity to en 50082-2 electrostatic discharge en 61000-4-2 level 2; 4 kv contact 1 level 3; 8 kv air 1 electromagnetic rf fields en 61000-4-3 level 3; 10 v/m 80 mhz - 1 ghz fast transients (burst) en 61000-4-4 level 4; 2 kv i/o level 3; 2 kv power rf conducted interference en 61000-4-6 level 3; 10 v/rms 150 khz - 80 mhz emissions to en 50081-1 rf interference en 55022 enclosure class b power mains class b note: 1. this device was designed for installation in an enclosure. to avoid electrostatic discharge to the unit in environments with static levels above 4 kv, precautions should be taken when the device is mounted outside an enclosure. when working in an enclosure, (ex. making adjustments, setting switches etc.) typical anti-static precautions should be observed before touching the unit. refer to emc installation guidelines for additional information. 9. construction : case body is black, high impact plastic. installation category i, pollution degree 2. 10. mounting : standard din rail top hat (t) profile rail according to en50022- 35 x 7.5 and 35 x 15 11. weight : 3.3 oz. (93.6 g) 8 5 4.7k rxb common 6 5 2 4 6 7 3 2 9 pin "d" connector 1 power in rs232 switches baud rate rd dte/dce switches td rs485 control tx rx 4 wire 2 wire/ 4.7k +5v txa 4 rxa txb termination 120 7 3 +vdc comm tx/rx tx/rx dtr dsr rts cts comm block diagram emc installation guidelines although red lion controls products are designed with a high degree of immunity to electromagnetic interference (emi), proper installation and wiring methods must be followed to ensure compatibility in each application. the type of the electrical noise, source or coupling method into a unit may be different for various installations. cable length, routing, and shield termination are very important and can mean the difference between a successful or troublesome installation. listed are some emi guidelines for a successful installation in an industrial environment. 1. a unit should be mounted in a metal enclosure, which is properly connected to protective earth. 2. use shielded cables for all signal and control inputs. the shield connection should be made as short as possible. the connection point for the shield depends somewhat upon the application. listed below are the recommended methods of connecting the shield, in order of their effectiveness. a. connect the shield to earth ground (protective earth) at one end where the unit is mounted. b. connect the shield to earth ground at both ends of the cable, usually when the noise source frequency is over 1 mhz. 3. never run signal or control cables in the same conduit or raceway with ac power lines, conductors, feeding motors, solenoids, scr controls, and heaters, etc. the cables should be run through metal conduit that is properly grounded. this is especially useful in applications where cable runs are long and portable two-way radios are used in close proximity or if the installation is near a commercial radio transmitter. also, signal or control cables within an enclosure should be routed as far away as possible from contactors, control relays, transformers, and other noisy components. 4. long cable runs are more susceptible to emi pickup than short cable runs. 5. in extremely high emi environments, the use of external emi suppression devices such as ferrite suppression cores for signal and control cables is effective. the following emi suppression devices (or equivalent) are recommended: fair-rite part number 0443167251 (rlc part number fcor0000) line filters for input power cables: schaffner # fn2010-1/07 (red lion controls # lfil0000) 6. to protect relay contacts that control inductive loads and to minimize radiated and conducted noise (emi), some type of contact protection network is normally installed across the load, the contacts or both. the most effective location is across the load. a. using a snubber, which is a resistor-capacitor (rc) network or metal oxide varistor (mov) across an ac inductive load is very effective at reducing emi and increasing relay contact life. b. if a dc inductive load (such as a dc relay coil) is controlled by a transistor switch, care must be taken not to exceed the breakdown voltage of the transistor when the load is switched. one of the most effective ways is to place a diode across the inductive load. most rlc products with solid state outputs have internal zener diode protection. however external diode protection at the load is always a good design practice to limit emi. although the use of a snubber or varistor could be used. rlc part numbers: snubber: snub0000 varistor: ils11500 or ils23000 7. care should be taken when connecting input and output devices to the instrument. when a separate input and output common is provided, they should not be mixed. therefore a sensor common should not be connected to an output common. this would cause emi on the sensitive input common, which could affect the instruments operation. visit rlcs web site at http://www.redlion.net/support/installationconsiderations. html for more information on emi guidelines, safety and ce issues as they relate to red lion controls products.
3 leds * switches in groups must be set * * off dce/ on dt e rs232 off dte/ on dce off dte/ on dce off dce/ on dt e * 6 5 7 on pull up pull down off 4 wire/ on 2 wire off 4 wire/ on 2 wire 120 terminatio n 38400 baud 115200 baud 57600 baud off 422/ on 485 off 422/ on 485 * 9 1 nc 2 3 4 10 6 7 8 3 4 5 red lion controls model icm5 york, pa . 9600 baud 19200 baud made in u.s.a. 9-26vdc class 2 @ 125ma max. 1 2 on m2869x rs485 txd rxd pwr rxa 7 comm 485/ rxb 422 txa 5 6 4 comm txb pwr sply + vdc 2 3 1 side view of icm5 typical rs-232 connections dip switch settings top bank of 10 switches switches 1-5 - baud select the appropriate baud rate. this adjusts the time delay for the automatic rs-485 driver controller. only one of the baud switches should be in the on position. switches 6-7 - pull up / pull down these switches connect 4.7 k ? biasing resistors to the a and b lines of the 485 receiver. to minimize loading of the network, these should only be used if no other device in the system provides biasing. switches 8-9 - off 4 wire / on 2 wire these switches can be used to internally jumper the a and b lines of the rs-485 driver and receiver together. this allows 2-wire operation without the use of external jumper wires. to use the rj-11 connector, the icm5 must be in 2-wire mode. both switches should be in the same position. switch 10 - 120 ? termination this switch connects a 120 ? resistor across the a and b lines of the rs-485 receiver. the use of the resistor prevents signal reflection, or echoing, at high baud rates, over long distances. this should only be turned on if the icm5 is the first, or last, device in a multi-drop network that is experiencing reflection due to long cable distances. bottom bank of 7 switches switches 1-2 - off 422 / on 485 these switches enable and disable the automatic rs-485 driver control. in the 422 position, the driver is always enabled, allowing 4-wire full duplex operation. in the 485 position, the driver is enabled as soon as characters are received on the rs-232 side. when the rs-485 driver has transmitted the last character, it waits one character time (at the selected baud rate), and then enters a high-impedance state. the receiver is also enabled and disabled in a similar fashion to prevent transmitted characters from being echoed back. this allows 2-wire, half-duplex operation, without the use of handshake lines. both switches should be in the same position. switch 3 - n/c no connection switches 4-7 - off dce / on dte these switches configure the rs-232 port to act as a dce or dte device. with all of the switches in the dce position, pin 2 of the db-9 connector is the rs-232 receiver, and pin 3 is the rs-232 transmitter. dte configures pin 2 as the transmitter, and pin 3 as the receiver. these switches allow the use of modem or null-modem cables. all of these switches should be in the dce or dte position. no other combinations are valid. off dte/ on dc e 120 termina tio n off 422/ on 485 off 422/ on 485 off dce/ on dt e off dce/ on dt e off dte/ on dc e pull down 9600 bau d 57600 bau d 1 15200 bau d off 4 wire/ on 2 wire 38400 bau d 19200 bau d off 4 wire/ on 2 wire on * * * * * * * 6 7 pull up 4 1 2 3 5 on 4 * * * * * nc 3 1 10 2 8 9 7 6 5 2 internall y jumpered 3 5 rx tx sig co m on on 1 15200 bau d 57600 bau d 38400 bau d pull down 9600 bau d 19200 bau d * * * * * pull up 6 5 4 3 7 * 1 2 * off dte/ on dce off dte/ on dce off dce/ on dt e off dce/ on dt e off 422/ on 485 off 422/ on 485 120 termina tio n off 4 wire/ on 2 wire off 4 wire/ on 2 wire 4 * * nc 3 2 1 * * * 9 8 10 5 6 7 jumpered internall y tx 2 sig co m 3 5 rx typical rs-422 connections notes: 1. connect shield (drain wire) to earth ground. 2. rs-422 polarity: terminal a is negative with respect to terminal b in the mark (logic 1) condition. 3 2 38400 bau d 9600 bau d 19200 bau d * * on 1 * off 4 wire/ on 2 wire off 4 wire/ on 2 wire 7 4 5 2 3 10 7 8 5 4 pull up pull down 57600 bau d 11 5200 bau d 120 terminat ion nc off 422/ on 48 5 off 422/ on 48 5 off dce/ on dt e off dce/ on dt e off dte/ on dce off dte/ on dce * * * * * 9 6 * * * * 6 1 on 4.7k 4.7k rx tx transmit da ta 3 receive da ta receive da ta signal common 5 6 b +5v 120 7 a transmit da ta a b 4 default settings baud rate 9600 dce 2 wire \ rs-485 no termination no pull-up or pull down dte dce typical rs-485 connections 2 1 3 19200 bau d 9600 bau d 38400 bau d off 4 wire/ on 2 wire off 4 wire/ on 2 wire 120 terminat ion 10 8 9 6 4 5 7 11 5200 baud 57600 bau d pull down pull up 7 6 4 3 nc 2 5 1 off dte/ on dce off dte/ on dce off dce/ on dt e off dce/ on dt e off 422/ on 48 5 off 422/ on 48 5 * * * on tx/rx b * * * * * * * * * 4.7k on signal common 6 5 a 4.7k +5v 120 7 note: connect shield (drain wire) to earth ground. note: connect shield (drain wire) to earth ground. note: connect shield (drain wire) to earth ground. * - application dependent * - application dependent * - application dependent * - application dependent
installation the unit is equipped with a universal mounting foot for attachment to standard din style mounting rails, including g profile rail according to en50035 - g32 , and top hat (t) profile rail according to en50022 - 35 x 7.5 and 35 x 15. the unit should be installed in a location that does not exceed the maximum operating temperature and provides good air circulation. placing the unit near devices that generate excessive heat should be avoided. g rail installation to install the icm5 on a "g" style din rail, angle the module so that the upper groove of the "foot" catches under the lip of the top rail. push the module toward the rail until it snaps into place. to remove a module from the rail, push up on the bottom of the module while pulling out away from the rail. t rail installation to install the icm5 on a "t" style rail, angle the module so that the top groove of the "foot" is located over the lip of the top rail. push the module toward the rail until it snaps into place. to remove a module from the rail, insert a screwdriver into the slot on the bottom of the "foot", and pry upwards on the module until it releases from the rail. typical rs-485 connections using rj-11 1 w/rj11 product red lion 4 7 10 11 5200 baud 57600 baud pull down 19200 baud 9600 baud 38400 baud off 4 wire/ on 2 wire off 4 wire/ on 2 wire 120 terminat ion * * * * on 2 1 3 * 10 8 9 6 4 5 7 pull up cable rs232 icm5 off dte/ on dce off dte/ on dce off dce/ on dt e off dce/ on dt e off 422/ on 485 off 422/ on 485 * * * * 7 6 4 3 nc 2 5 1 on rj-1 1 jumper cbj1 1bd5 8 9 11 12 23 6 5 troubleshooting for further technical assistance, contact technical support at the appropriate company numbers listed. model no. description part number cbj icm5 6" rj-11 jumper cable rs-232/rs-485 converter module cbj11bd5 ICM50000 ordering information typical connection for rs-485 devices off dce/ on dt e off dce/ on dt e off dte/ on dce off dte/ on dce pull down 38400 bau d 9600 baud 19200 bau d 57600 bau d 1 15200 bau d off 422/ on 485 off 422/ on 485 120 termina tion pull up off 4 wire/ on 2 wir e off 4 wire/ on 2 wir e 7 6 8 on 7 * * * * * 2 5 3 4 1 6 rxa rxb * * 4 nc 2 3 1 9 10 on * * 6 7 5 2 3 5 4 txb spl y pwr comm txa comm 485/ 422 1 + vdc +vdc comm. tx/rx (+) tx/rx (-) 11 legend 3 1 2 tx en. 10 67 8 9 4 5 rs485 comm 1 3 2 n/c 11 8 7 45 6 91 0 tc comm n/c rt d 3 12 ac ~~ ac user inputs rl y4 comm 24 25 rl y3 rl y2 22 23 rl y1 comm 20 21 15 13 14 out - - out + 20ma 12 + 10v - n/c 15 14 - common - a(+) 13 12 - b(-) pa x note: for connections to rs485 port on pa radigm products, a & b are reversed . * - application dependent * - application dependent


▲Up To Search▲   

 
Price & Availability of ICM50000

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X